If we talk about operational costs of compressed air plants we are actually talking about the energy costs as they make up about 70 to 80 % of the total costs of a compressed air plant.

Depending on the size of the plant this means considerable operating costs. Even in smaller plants, this may quickly add up to 10 000 to 20 000 € per year. This is an amount which can be considerably reduced – even in the case of well operated and maintained plants.

For sure this also applies to your compressed air plant! Which actual costs per generated m³ air do you actually have? Which energy is gained due to the waste heat recovery? What is the total performance balance of your plant? How high are the differential pressures of single filters? How high is the humidity (pressure dew point)? How much-compressed air is used?

By means of the intelligent chart recorder DS 500 or DS 500 mobile and the suitable sensors and meters, all these questions can be answered easily. For example by means of a long-term measurement over 7 days, data recording and evaluation at the PC.

Your advantages of DS 500 mobile at a glance

  • Easy and clear layout
    • Very easy operation via 7″ color display with touch panel
  • Versatile:
    • Up to 12 sensors/meters connectable also third-party sensors/meters including power supply
  • Reliable:
    • Stores all measured values on a memory card, easy reading-out via USB stock possible
  • Intelligent energy analysis:
    • Daily/weekly/monthly evaluations mathematic function for internal calculations, e.g. the typical key data of a compressed air plant

Intended use

The DS 500 data logger serves for the stationary measured data acquisition and storage of analog and digital input signals. The DS 500 data logger is exclusively designed and constructed for the proper application purpose
that is described herein and must only be used correspondingly.

A check in order to ascertain whether or not the device is suitable for the chosen employment must be
carried out by the user. It must be ensured that the medium is compatible with the components which
come into contact with it. The technical data listed in the datasheet are binding.

Improper handling or operation outside the technical specifications is impermissible. Claims of any
kind on the basis of improper use is excluded.

Specification

TYPE
DS 500 DS 500 Mobile
Dimensions
280 x 170 x 90 mm, IP 65
360 x 270 x 150 mm
Weight 7.3 Kg 4,5 kg
Material Die cast metal, front screen polyester Diecast, front foil polyester, ABS
Sensor inputs 4/8/12 sensor inputs for analogue and digital sensors; freely allocatable
Digital CS sensors for dew point and consumption with SDI interface FA/VA series, digital third-party sensors RS 485 / Modbus RTU, other bus systems realizable on request.
Analogue CS Sensors for pressure, temperature,clamp-on ammeters preconfigured
Analogue third-party sensors 0/4…20 mA, 0…1/10/30V, pulse, Pt 100 / Pt 1000, KTY
Power supply for sensors:
24 VDC, max. 130 mA per sensor, integrated mains unit max. 24 VDC, 25 W.
In case of version 8/12 sensor inputs,2 integrated mains units each max. 24 VDC, 25 W.
Interfaces USB stick, Ethernet / RS 485 Modbus RTU / TCP, SDI other bus systems on request, WEB server optionally,GSM modul(DS 500 Mobile)
Memory card
Memory size 4 GB SD memory card standard
Power supply 100…240 VAC / 50-60 Hz, special version 24 VDC (DS 500)
Color screen 7“ touch panel TFT transmissive, graphics, curves, statistics
Accuracy Please see sensor specifications
Operating temperature 0…50°C
Storage temperature -20…70°C
Options
Webserver
energy and flow report“ statistics, daily/weekly/monthly report