Flowmasonic

ABB FCB400 Coriolis Mass Flowmeters
ABB FCB400 Coriolis Mass Flowmeters

ABB FCB400 Coriolis Mass Flowmeters

1 minute, 38 seconds Read

ABB FCB400 Mass Flowmeters series of compact Coriolis mass flowmeters feature low-pressure drop, high capacity, intuitive ABB common display, five modular I/O`s, and HART communication.

Coriolis Master FCB 400

With no up or downstream piping requirements, the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before.

ABB FCB400 Mass Flowmeters series delivers:

  • Up to five modular I/Os
    – Multivariable meter design
    – Optional plug-in cards
    – Automatic firmware update
  • SmartSensor
    – All digital solution
    – Installation flexibility
    – Meter intelligence located in the sensor
  • SensorApplicationMemory
    – Maximum data security
    – Plug and play electronics replacement
  • ABB common look and feel
    – Easy Set-up
    – Operation through the glass via capacitive keys
  • VeriMass on-board verification and diagnostics
    – Online preventive maintenance
    – Extended maintenance cycles
    – Reduced maintenance effort
  • Designed for 70 °C (158 °F) ambient temperature and high vibrations
  • Lower pressure drop
  • Self-draining
  • Global approvals for explosion protection

The FCB450 adds:

  • DensiMass software for direct concentration measurement
  • FillMass software for filling application control
  • Nominal sizes/measuring ranges
    – DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
    – DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
    – DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
    – DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
    – DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
    – DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h)
  • Ex approvals
    – ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2
  • Wetted materials
    – 1.4404 / 1.4435 (316L) or Hasteloy C
  • Accuracy for liquids
    FCB430
    – Mass and volume: 0.4 % o. r. / 0.25 % o. r. / 0.2 % o. r.
    – Density: 10 g/l
    FCB450
    – Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
    – Density: 2 g/l or 1 g/l
  • Measuring medium temperature
    FCB430
    –  -50 to 160 °C (-58 to 320 °F)
    FCB450
    –  -50 to 205 °C (-58 to 400 °F)
  • Outputs
    – 5 modular I/Os
    – HART 7.1
    – PROFIBUS DP
    – Modbus
  • Power supply
    – 11 to 30 V DC, 110/230 V AC

Download Datasheet: FCB 400