Omron E8FC IoT Flow Sensor ‘Onsite IoT’ uses production floor data to help minimize machine downtime and backtracking and increase machine operation stability and productivity. Offering a wide variety of components including sensors and controllers and further expanding the IoT product lineup to collect onsite data, OMRON can totally help you bring IoT innovation to your manufacturing sites.

Omron E8FC IoT Flow Sensor Features

  • Multi-sensing of “Flow rate + temperature” for preventing sudden stops or manufacturing
  • Various lineup of replacement adapters to enable easy replacement of your current pressure gauges and flow
  • Analog current output function in addition to the IO-Link communications function can perform self-diagnosis of abnormalities in the sensor
     Another Article:

Specifications

Model PNP (COM2) E8FC-25D
PNP (COM3) E8FC-25T
NPN E8FC-25
Applicable
diameter
Nominal diameter B 3/8″ 1/2″ 3/4″ 1″
Nominal diameter A 10 A 15 A 20 A 25 A
Applicable fluid The fluid must not corrode the material of the wetted part (for example, water or a fluid whose conductivity is equivalent to that of water).
Permissible pressure *1 10 MPa
Flow rate
monitoring
*2
Rated flow rate range 0.6 to 14 l/min 1 to 30 l/min 1.5 to 60 l/min 2 to 100 l/min
Inner diameter setting (10 A, 15 A, 20 A, 25 A)
Display range 0 to 16 l/min 0 to 33 l/min 0 to 66 l/min 0 to 110 l/min
Zero cutting flow rate *3 0.6 l/min 1 l/min 1.5 l/min 2 l/min
Display resolution (l/min) 0.1/1 (Selectable)
Flow rate monitoring
response time
Control output: 1.0, 2.5, 5, 10, 30, 60 s
Flow rate monitoring
precision
± (7.0% of measured value + 2.0% F.S.) or less
Flow rate repeatability / F.S.
(prescribed for each
response time)
1 s: ±3.5%, 2.5 s: ±2.5%, 5 s: ±1.6%, 10 s: ±1%, 30 s: ±0.8%, 60 s: ±0.6%
Ambient temperature
characteristics *4
±1.0% F.S./10°C
Hysteresis Variable
Temperature
monitoring
*5
Temperature monitoring
rated range
0 to 85°C
Temperature monitoring
precision
±2.5°C
Temperature repeatability ±0.5°C
Control
output
judgment
(selectable)
Standard mode Judge if the measured value is the threshold value or more (or less).
Window mode Judge if the measured value is within the upper and lower limits.
Display method Numerical value indication: 4-digit 7-segment white LED with inverting function
Status indicators: The content of indication is selectable from green, orange, red, and OFF.
Output indicator: OUT1 operation (orange), OUT2 operation (orange)
Unit indicator: l/min (White), % (White), °C (White), ST (White)
Communication indicator: Lighting when communications are in progress (green)
Delay setting 1 to 9999 ms (Select a function from invalid, ON delay, OFF delay, and one-shot.)
Connection method M12, 4-pole connector type
Output ch1
(selectable)
Control output Flow rate control output (N.O./N.C.)
E8FC-25D/-25T: PNP
E8FC-25: NPN
30 VDC or less, Class 2, 100 mA max., residual voltage 1 V or less
Pulse output 1/ 10/ 100/1000 l
Output ch2
(selectable)
Control output Flow rate control output (N.O./N.C.) / temperature control output (N.O./N.C.)
E8FC-25D/-25T: PNP
E8FC-25: NPN
30 VDC or less, Class 2, 100 mA max. residual voltage 1 V or less
Analog current output *7 Flow rate analog output /temperature analog output
Current output 4 to 20 mA (maximum load resistance 350Ω or less)
(Display value ± 2% of F.S.)
Pulse output 1/ 10/ 100/1000 l
External input Smart tuning, One-point tuning,
short-circuit current 1.5 mA or less, input time 20 ms or more
IO-Link IO-Link specification Ver 1.1
Baud rate E8FC-25D: COM2 (38.4kbps)
E8FC-25T: COM3 (230.4Kbps)
Data length PD Size: 6 byte
OD Size: 1 byte (M-sequence type: TYPE_2_V)
Minimum cycle time E8FC-25D (COM2): 3.2 ms
E8FC-25T(COM3): 2.0 ms
Power
supply
Power supply voltage 15 to 30 VDC (including 10% ripple (p-p)), Class 2
Power consumption 2,880 mW or less
(When power supply voltage is 30 V, current consumption must be 96 mA or less.
When power supply voltage is 15 V, current consumption must be 192 mA or less.)
Protection circuit Power supply reverse connection protection, output short-circuit protection, and output reverse connection protection
Environment
resistance
Ambient temperature
range
-20 to 80°C in operation and storage, respectively (no condensation)
Applicable fluid
temperature
0 to 85°C (no icing on the pipe surface)
Ambient humidity range 35 to 85%RH in operation and storage, respectively (no condensation)
Withstand voltage 500 VAC 50/60 Hz 1min
Vibration resistance
(destruction)
10 to 2000 Hz, double amplitude 1.5 mm, 2 hours in X/Y/Z direction each
Shock
resistance
(destruction)
500 m/s2, three times in X/Y/Z direction each
Protective structure IP67
Pollution degree 3
Altitude 2,000 m or less
Installation place Indoor
Materials Wetted part Detecting unit: SUS304L, O-ring: FKM
Other than wetted part Head: PPSU, display unit: PES, button: PBT, chassis: SUS304L, nut: SUS304
Weight Approx. 190 g
Accessories • Ferrite core x 1 (TDK’s Model ZCAT1 730-0730A)
• User’s manual (Japanese, English, and Chinese), one each
• Compliance sheet
• Index list