WUF 620 CF series clamp-on transit-time ultrasonic flow meter utilizes transit-time principle. The transducer is mounted outside surface of the pipe without requirements of flow stop or pipe cutting. It’s very simple, convenient for installation, calibration and maintenance. Different sizes of transducers satisfy different measuring demand. Plus, select thermal energy measuring function to achieve completely energy analysis. It is widely applied in processing monitoring, water balance test, district heating balance test, energy efficiency monitoring as easy installation and simple operation advantages.
WUF 620 CF With Panel box
WUF 620 CF Flow Transmitter
WUF 620 CF Flow Transducer
Features
4 Lines Display Velocity, Flow Rate, Volume And Meter Status
Clamp-on Mounted, Unnecessary Pipe Cutting Or Processing Interruption
Acceptable Fluid Temperature Range -40°C~85°C
Built-in Data Storage Is Optional
Selecting Temperature Sensor PT1000 To Achieve Thermal Energy Measurement Function
Suitable For DN20-DN6000 Flow Measurement By Selecting Different Size Transducers
Insertion flow meter is suitable for measuring DN65-6000 pipeline flow
Bi-directional measurement, flow range from 0.01m/s to 12m/s
Available for transducers with water proof or ip68 class
Available dual power supply 220 VAC and 24 VDC
Flowmasonic WUF 620 CF Ultrasonic Clamp-On Flow Meter
Applications
Water Utility
Water Conservancy & Resource
College & University
Manufacturing
Draining Company
Heating Supply Industry
Petrochemical Industry
Specification
Measuring Principle Transit-time Velocity 0.01 – 12 m/s, Bi-directional Measurement Resolution 0.25mm/s Repeatability 0.1% Accuracy ±1.0% R Response Time 0.5s Sensitivity 0.003m/s Damping 0-99s(settable by user ) Suitable Fluid Clean or tiny amounts of solids, air bubbles liquid , Turbidity <10000 ppm Power Supply AC: 85-265V DC:12- 36V/500mA Installation Wall Mounted Protection Class IP66 Operating Temperature -40℃ to +75℃ Enclosure Material Fiberglass Display 4X8 Chinese Or 4X16 English,Backlit Measuring Unit meter,ft,m³,liter,ft³,gallon,barrel etc. Communication Output 4~20mA, OCT, Relay, RS485 (Modbus-RUT), Data Logger ,GPRS Energy Unit Unit : GJ,Opt: KWh Security Keypad Lockout, System Lockout Size 244*196*114mm Weight 2.4kg
Transducer
Protection Class IP67 Fluid Temperature Std. transducer : -40℃~85℃(Max.120℃) Pipe Size 20mm~6000mm Transducer Size S 20mm~50mm M 40mm~1000mm L 1000mm~6000mm Transducer Material Std. Aluminum alloy, High Temp.(PEEK) Temperature Sensor PT1000 Cable Length Std. 10m (customized)