Flowmasonic

Electromagnetic Alia Flow Meter- AMF 900
Electromagnetic Alia Flow Meter- AMF 900

Electromagnetic Alia Flow Meter- AMF 900

1 minute, 34 seconds Read

Alia Flow Meter | Alia Electromagnetic flow Meter

AMF900 SeriesElectromagnetic Flow Meter

AMF900 Series is a flange type Electromagnetic Flowmeter ideal for conductive liquids. It comes in sizes from 6 to 2000mm. AMF900 is widely used for tap-water, wastewater, food & beverage, Pulp & Paper, and much other industrial fluid.

flow meter

 

AMF900 Series electromagnetic flowmeter could be used in the compact or separate models with AMC Series converter of electromagnetic Flowmeter.

FEATURES

  • Various liner and electrode can be selected to satisfy most industrial applications
  • Flow Velocity range:0-12 m/s, with precise measure for low flow applications
  • It comes to any flanges such as ANSI, DIN, JIS… etc
  • Excellent for high-pressure application
  • Protection class: IP68 is available, and the sensor can sink into the water
  • FEP Liner is suited for vacuum tube
  • High accuracy of +/-0.4% value of reading (or +/-0.2% value of reading)
  • With forwarding/Reverse flowrate measure function

SPECIFICATION

Size: Electrode & Grounding:
6,10,15,20, 25,32,40,50,65,80,100,125 Stainless Steel 316L
150,200,250,300,350,400,450,500,600 Hastelloy B
700,800,900,1000,1200,1400,1600 Hastelloy C
1800,2000 mm Titanium
Measuring Range: Tantalum
Velocity   0 – 0.25 m/s min. Platinum
                0 – 12  m/s max. Tungsten Carbide
Material: Cable Entry:
Measuring Tube PG11
Stainless Steel 304 Ambient Temperature:
Flange
-25 to +60 oC
Carbon Steel (standard) Process Connection:
Stainless Steel 304(Option) Flange
Stainless Steel 316,316L(Option) Flanges Type:
Coil Housing JIS 10K / JIS 20K / JIS 40K
Carbon Steel (standard) ANSI 150# / ANSI 300# / ANSI 600#
Stainless Steel 304(Option) DIN PN 10 / PN 16 / PN25 / PN 40
Stainless Steel 316,316L(Option) Grounding Resistance:
Liner: Must be  less then 10 
Polyurethane(25-600 mm) Accuracy:
Neoprene(50-2000 mm) +/-0.4% read-out values(Velocity>=0.5 m/s)
FEP(6-300 mm) +/-0.0025 m/s (Velocity < 0.5 m/s)
PTFE(25-800 mm) +/-0.2% read-out values
PFA(6-300 mm) (suit for AMC3100 Converter only)
IP 68 Temperature:
IP 68 (Submersible)
-10 ~ +60 oC (Polyurethane,PU)
Conductivity:
-20 ~ +70 oC (Neoprene)
More than 5 uS/cm
-40 ~ +180 oC (FEP)
Explosion Proof:
-40 ~ +180 oC (PTFE/PFA)
Exd(ib)ibqIIBT5 (with AMC3100 only) Max. Pressure:
350 Kg/cm2