Since 1990, Seametrics flow measurement has been providing high-value flow meters and controls. The guiding principles have been common sense, simplicity, economy and durability. We started with mechanical insertion meters that extended the bottom of the flow range and were easy to repair. Over the years our flow meter product family has expanded to include electronic turbine flow meters, inexpensive and highly accurate mechanical low-flow meters, and a variety of flow meter controls and displays. In recent years Seametrics has become a leading manufacturer of electromagnetic meters (mag meters) in a variety of designs suitable to a wide range of applications. These include insertion, spool, and low-flow chemical-resistant mag meters.
WMX Series Electromagnetic Flow Meter
FEATURES
|
APPLICATIONS
|
Pipe Sizes
|
3”,4”, 6”, 8”, 10”
|
||||||||
Fittings
|
ANSI 150 lb. drilling
|
||||||||
Pressure
|
150 psi (10.3 bar) working pressure
|
||||||||
Temperature Operating
|
10˚ to 130˚ F (-12˚ to 54˚ C)
|
||||||||
Non-Operating
|
-40˚ to 158˚ F (-40˚ to 70˚ C)
|
||||||||
Accuracy
|
+/- 1% of reading for flow between 10
|
||||||||
Materials
|
Body (3” Only)
|
Ductile cast iron, powder coated w/NSF61 listed epoxy powder
|
|||||||
Body (4”-10”)
|
Welded steel, epoxy-coated
|
||||||||
Liner (3” Only)
|
Noryl®
|
||||||||
Liner (4”-10”)
|
Dual durometer rubber
|
||||||||
Electronics Housing
|
Diecast aluminum, powder-coated (non-IP68)
|
Ductile Cast Iron (IP68)
|
|||||||
Electrodes
|
316 stainless steel
|
||||||||
O-ring (3” Only)
|
EPDM
|
||||||||
Display
|
Digits
|
Rate
|
Total
|
||||||
5
|
8
|
||||||||
Units
|
Gallon/Minute, Liter/Minute, Liter/Second, Cubic Feet/Minute, Cubic Meter/Hour, Million Gallon/Day, Mega Liter/Day
|
Gallon, Gallon x 1000, Liter, Liter x 1000, Mega Liter, Cubic Meters, Cubic Meter x 1000, Cubic Feet, Million Gallon/Day, Mega Liter/Day Cubic Feet x 1000
|
|||||||
Power
|
WMX101:8-32 Vdc at 30 mA max, with auxiliary battery for continuous operation during power failures
NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation
|
||||||||
WMX104 : 2 Lithium 3.6V “D” batteries, replaceable, 1 year life under continuous use
|
|||||||||
Pulse Output
|
Signal
|
WMX101 : Current sinking pulse, opto-isolated, 30 Vdc at 10 mA max
|
|||||||
WMX104 : Pulse output available only with addition of post-factory output cable
|
|||||||||
Pulse Rates
|
High Frequency (default); 10 units/pulse; 100 units/pulse; 1000 units/pulse
|
||||||||
High Frequency
(pulse/gal)
|
3”
|
4”
|
6”
|
8”
|
10”
|
||||
25.228
|
16.362
|
6.307
|
3.344
|
2.150
|
|||||
Conductivity
|
>20 microSiemens/cm
|
||||||||
Empty Pipe Detection
|
Hardware/software, conductivity-based
|
||||||||
Environmental
|
NEMA 4X Standard (IP68/NEMA 6P Option )
|