Flowmasonic

Flowmasonic WUF 500 Clamp On Ultrasonic Flow Meter For Water
Flowmasonic WUF 500 Clamp On Ultrasonic Flow Meter For Water

Flowmasonic WUF 500 Clamp On Ultrasonic Flow Meter For Water

The WUF 500 is a state-of-the-art universal transit-time Flow meter designed using SLSI technology and low voltage broadband pulse transmission. While principally designed for clean liquid application, the instrument is tolerant of liquids with small amounts of air bubbles or suspended solids found in most industrial environment.

Baca juga: WUF 100 CF Flowmasonic Clamp On Ultrasonic Flow Meter

Features

WUF 500 Flowmasonic

WUF 500 Flowmasonic Clamp on

With distintive features such as high precision, high reliability, high capability and low cost, the Flowmeter features other advantages:

1. SLSI technology designed. Less hardware component, low voltage broadband pulse transmission, low consumption power, high reliability, anti-jamming and outstanding applicability.

2. User-friendly menu designed. Parameter of pipe range, pipe material, pipe wall thickness, output signal, etc. can be conveniently entered via the windows.
U.S., British and Metric measurement units are available.

3. Daily, monthly and yearly totalized flow: Totalized flow for the last 64 days and months as well as for the last 5 years are may be viewed.
Power 0n/off function: allow the viewing of time and flow rate as power is switched on and off 64 times. Also, the Flowmeter has manual or aotumatic amendment during offline sessions.
Self-contained signal output, open collector, frequency.

4. Parallel operation of positive, negative and net flow totalizes with scale factor (span) and 7 digit display, while the output of totalize pulse and frequency output transmitted via open collector.

Specification

Performance specifications
Flow Range 0∼±16 ft/s (0∼±5m/s)
Accuracy ±1.0% of measured value (for 0.5∼4.0 m/s or 1.5∼13 f/s)
Repeatability 0.3%
Pipe Size 1 inch to 32 inch (25 mm to 800 mm)
Fluid Water
Pipe Material Carbon Steel, Stainless Steel, PVC, Copper, Aluminium, Fiber Glass, Cast Iron, etc.
Fuction Specifications
Outputs Pulse Output: 0∼9999 Hz, OCT, (min. and max. frequency is adjustable)
Relay Output : 1A/30VDC, 0.3A/125VAC
Analog Output (Optional): 4∼20mA max load 750Ω
Input Interface (optional) RTD 2*PT100 interface exclude PT100 transducer
Two wires or three wires system 0 180 32 35
Communication Inteface RS323 (standard)
RS485 (optional)
Baud rate 9600bps∼115200bps
Power Supply 10∼24VAC or 10∼36 VDC 1A (max)
Keypad 16 ( 4×4) key with tactile action
Display 40 character,, 2 line (20×2) lattice alphanumeric, backlit LCD
Temperature Tranmitter: -10ºC∼50ºC
Transducer: 0ºC∼60ºC
Humidity Up to 99% RH, non-condensing
Physical Specifications
Transmitter PC/ABS IP65
Transducer Encapsulted design,IP68
Duoble-shielded Transducer Cable Standard/Maximum cable lenght: 30 ft/ 1000ft (9m/305m)
Weight Transmitter: approximately 0.7 kg
Transducer: approximately 0.4 kg

Visit Wmablog for more info and price or

Buat Penawaran

Similar Posts

Skip to content