PE 202 Flow Magmeter
The PE 202 Seametrics Low-Flow Magmeter is designed for low-flow chemical injection or difficult-to-meter applications with pulsating metering pumps in 3/4” to 1/4” pipe/tube. The housing is made of sturdy splashproof HDPE plastic.
With no moving parts, the PE202 can handle fluids containing particulate matter without clogging or jamming, keeping maintenance at a minimum. With no metallic parts (100% PVDF body and PVDF carbon fiber-filled electrodes), the meter is corrosion-resistant and compatible with a wide range of chemicals. Accuracy is maintained with conductive fluids (>20 micro siemens) of varying viscosities and densities.
The PE meter is compact enough to fit most pump/injection systems. With zero straight pipes required after an elbow, it can be easily mounted in tight spaces. The mounting bracket adds stability.
The PE meter has an optoisolated current-sinking pulse output that can be connected to the Seametrics FT430/440 rate/total display or FT520 batch processor, as well as an optoisolated 4-20 mA current loop for powering analog devices. Outputs and power are provided through a 20 foot (6 meters) cable with an 8-pin female circular connector.
Feature
- No moving parts
- Requires no straight pipe
- Pulse and/or 4-20 mA output
- Chemical and corrosion-resistant
- Insensitive to fluid density and fluid viscosity changes
Application
- Chemical injection
- Corrosive materials
- Low flow applications
- Pulsating flows (e.g., metering pump)
Specification
Pipe Size | 3/4”, 1/2”, 3/8”, 1/4” | |
Fittings | 1/2” NPT fittings standard in 3/4” or 3/8” flow body. NPT threaded adapters are available for the above pipe sizes. | |
Materials | Body | PVDF |
Electrodes | PVDF carbon fiber filled | |
Ground | PVDF carbon fiber filled | |
Housing | HDPE with 25% glass | |
Adapters (NPT) | Polypropylene or PVDF | |
Temperature | Ambient | 0 ̊ to 130 ̊ F (-18 ̊ to 54 ̊ C) |
Fluid | 32 ̊ to 200 ̊ F (0 ̊ to 93 ̊ C) | |
Pressure | 150 psi | |
Flow Range | -075 | 20 GPM max. (0.2 GPM cutoff) |
-038 | 3 GPM max. (0.03 GPM cutoff) | |
Accuracy | -075 | ±1% plus ±0.005 GPM of reading across a rated range |
-038 | ±1% plus ±0.002 GPM of reading across a rated range | |
Output Signal |
Optoisolated current sinking or current sourcing pulse output: 30 Vdc, 5 mA max
Optoisolated 4-20 mA current loop: 7 Vdc plus load voltage drop min; 50 Vdc max
|
|
-075 | 500 pulses/liter (1892 pulses/gallon) | |
-038 | 1000 pulses/liter (3785 pulses/gallon) | |
Power | 10–15 Vdc, 150 mA (linear power supply recommended) | |
Conductivity | >20 micro siemens | |
Empty Pipe Detection | Hardware/software, conductivity-based | |
Environmental | NEMA 4X standard; IP66 splashproof standard |
Download Datasheet: Seametrics PE202
Info lebih lanjut hubungi : marketing@wmablog.com