Flowmasonic

Sage Flow meter gas
Sage Flow meter gas

Sage Flow meter gas

1 minute, 7 seconds Read

SPECIFICATION :

STYLE: Remote Insertion Mass Flow Meter

SENSOR: Two reference-grade platinum RTD clad in 316SS sheath

MATERIAL: Wetted metal components: 316SS

POWER: 24VDC Standard (12VDC or 115/230VAC optional)

POWER DISSIPATION:

ELECTRONICS: Remote-Style Microprocessor-based (Hybrid-Digital)

PROBE ENCLOSURE: Junction Box is Explosion Proof, Class I, Div 2, Groups B, C, D (no electronics)

TRANSMITTER ENCLOSURE: Remote mount, NEMA 4 enclosure

DISPLAY: High contrast photo-emissive OLED graphical display (Flow Rate, Totalizer, Temperature)

TURNDOWN: 100 to 1

RESOLUTION: 1000 to 1

LOW-END SENSITIVITY: 5 SFPM

FIELD CALIBRATION CHECK: Yes – Digital system allows raw signal validation (milli-watts)

COMMUNICATIONS: Modbus® compliant RS485 RTU or optional HART® communications

APPROVALS: CSA C22.2 (24 VDC); ULI604, Class I, Div 2, Groups B, C, D T4 (24VDC);

CE (AC Power or 24VDC)

FIELD RECONFIGURABLE: Sage ADDRESSER required

FLOW ACCURACY: +/- 0.5% of Full Scale +/- 1% of reading (Enhanced accuracy optionally available with limited turn-down)

FLOW REPEATABILITY: 0.2%

RESPONSE TIME: 1 second time constant

GAS TEMPERATURE RANGE: Standard -40° to 200°F (93°C), Optional to 300°F (149°C) and 450°F (232°C)

GAS PRESSURE: 500 PSIG (If higher pressure needed, contact Sage)

FLOW OUTPUT: 4 to 20 mA for Rate

TOTALIZER: 24VDC pulse for Totalized value

TEMPERATURE OUTPUT: Through Modbus® only

AMBIENT TEMPERATURE: -40°F to 150°F (66°C)

PROBE STYLE / LENGTH: 1/2″ OD Probe (3/4″ optional) Lengths 6″ to 36″

RELAYS: N/A

CABLE LENGTH: 25′ Standard (max length 1000′)

FLOW CONDITIONING: Captive Flow Conditioners available upon request with meter purchase

TRANSMITTER ENCL DEPTH: DC: 4.35″ ; AC: 5.35″

Info : marketing@wmablog.com

 

Similar Posts

Skip to content