Setting Standards in Clamp-on Ultrasonic Gas Flow Measurement
The FLUXUS G721 is a technological breakthrough in the ultrasonic clamp-on volume and mass flow measurement of gases.With its state-of-the-art hardware design and powerful digital signal processing it surpasses any other non-intrusive ultrasonic gas flowmeter in terms of accuracy, reliability and versatility.
Highly sophisticated signal filters, faster than ever processing capacities and advanced measurement algorithms make the FLUXUS G721 gas flow meter the standard setting measuring solution for any industrial application – even for the most challenging ones.
The meter adapts itself automatically to the respective measurement conditions and compensates for flow profile disturbances such as beam dispersal and structure-borne noise, allowing for even more precise and reliable measurements. Extreme fast measurement cycles enable precise real time monitoring of highly dynamic processes.
Baca juga: WUF 100 CF Flowmasonic Clamp On Ultrasonic Flow Meter
Applications
- Chemical industry
- Petrochemical industry
- Oil and gas industry
- Manufacturing industries
Specification
Measurement uncertainty (volumetric flow rate) |
± 1…3 % of reading ±0.02 ft/s |
Repeatability | 0.15 % of reading ±0.02 ft/s |
Flow velocity range | 0.03 to 115 ft/s, depending on pipe diameter |
Ex zone transmitter | ATEX/IECEx Zone 2 |
FM Class I /Div 2 | |
Power supply | 100-230VAC, 24DC, 12DC |
Available transducer | Shear wave/Lamb wave |
for Ex zones | ATEX/IECEx Zone 1/Zone 2 |
FM Class I – Div2 | |
for pipe sizes range | 0.28 inch to 63 inch |
for temperature range | -40°F to +392°F / WI : -328°F to +1112°F |
Outputs | 4-20mA active/passive |
4-20mA HART active/passive | |
pulse/frequency/binary | |
Inputs | Pt100/Pt1000 |
4-20mA active/passive | |
Binary input | |
Digital communication | Modbus RTU/TCP |
BACnet MSTP/IP | |
Profibus PA | |
Foundation Fieldbus | |
Additional Information | For more detailed Information please download the Data Sheet |
Data sheet Flexim- Fluxus G721