WMAG30 series electromagnetic flow meters are specializing in measuring conductive liquid (conductivity> 5μs/cm). These series flow meters have high applicability for low flow rate, sewage, acid and alkali liquid, low abrasive slurry. Our products have advance intellective-tech, field show and communicator.
Application
Electromagnetic flow sensors WMAG30 are precision measuring devices, suitable for determining the flow rate of nearly any electrically conductive fluid, but also for substances such as sludge, pulp and paste. Due to the magnetic field, the device can be used to measure flow rates up to 10 m/s (32.8 ft/s) and a minimum conductivity of 5 µS/cm, when using a synchronized static field. The entire measuring device comprises a flow sensor and a dedicated transmitter. Those can be delivered either separately or as a compact unit. The electromagnetic flow sensors mag-flux A are applied mainly in the following industries:
- Water and sewage plants
- Chemical and pharmaceutical indu
- Food and beverage industry
- Mining, cement and mineral mate
- Pulp and paper industry
- Steel industry
- Energy industry, public utilities
Specification :
- Size : DN10 – DN2000
- Velocity range : 0.01m/s to 10 m/s
- Accuracy : ±0.5% or ±0.2% ten point nonlinear correction
- Pressure rating : PN1.6 to PN40 MPa, ANSI Class#150/300/600/900, JIS10k/20k
- Power supply : 24VDC or 110VAC or 220VAC or battery
- Output signal : 4-20mA and pulse
- Alarm signal : high and low alarm output
- Unit : m3, liter, gallons, ton(t) , kg
- Display : LCD , 3-line, Velocity, flow rate and total flow
- Communication : Hart or RS485 ( mod bus )
- Fluid Temperature : up to 180 ℃
- Process connection : Flange , PN1.6 / ANSI #150
- Electrode material : SUS316L, Hastelloy, Titanium, Tantalum
- Lining material : Chloroprene Rubber, PTFE, PU, PFA
- Body material : SUS304 or SUS316
- Flange material : Carbon Steel or SUS304 or SUS316
- Process Connection : Flange or Threaded or Clamp connect
- Cover material : Carbon Steel, SUS304
Flow Range
Size | Qmin (mᶟ/h) | Qmax (mᶟ/h) | Size | Qmin (mᶟ/h) | Qmax (mᶟ/h) | Size | Qmin (mᶟ/h) | Qmax (mᶟ/h) |
DN20 | 0.11 | 11 | DN125 | 4.4 | 441 | DN500 | 71 | 7065 |
DN25 | 0.18 | 18 | DN150 | 6.4 | 635 | DN600 | 102 | 10170 |
DN32 | 0.29 | 29 | DN200 | 11.3 | 1130 | DN700 | 139 | 13840 |
DN40 | 0.45 | 45 | DN250 | 17.7 | 1766 | DN800 | 181 | 18080 |
DN50 | 0.71 | 71 | DN300 | 25.5 | 2543 | DN900 | 229 | 22890 |
DN65 | 1.19 | 119 | DN350 | 34.6 | 3461 | DN1000 | 283 | 28260 |
DN80 | 1.81 | 180 | DN400 | 45.2 | 4521 | |||
DN100 | 2.83 | 282 | DN450 | 57.3 | 5722 |
Size Data
Installation
Model Number
WMAG30 | 10 | 16 | 2A | 1 | OO | R | /N | Detail description |
WMAG31 | Heatexchanger industry for flowmeter | |||||||
20 | DN20 | |||||||
– | ||||||||
1000 | DN100 | |||||||
10 | PN1.0 Mpa | |||||||
16 | PN1.6MPa | |||||||
25 | PN2.5MPa | |||||||
40 | PN4.0MPa | |||||||
2A | PTFE lining,316L electrode | |||||||
1A | rubber lining,316L electrode | |||||||
0 | 220V.AC | |||||||
1 | 24V.DC | |||||||
OO | Integral type, IP65 | |||||||
10 | Split type, IP65 | |||||||
11 | Split type, IP698 | |||||||
R | RS485(modbuse protoco) | |||||||
N | No communication | |||||||
/N | No cable (integral type) | |||||||
/**m | **meter cable (split type) |