Flowmasonic

Delta Elektrogas VMM Multiple safety solenoid valve for gas regulating trains
Delta Elektrogas VMM Multiple safety solenoid valve for gas regulating trains

Delta Elektrogas VMM Multiple safety solenoid valve for gas regulating trains

2 minutes, 12 seconds Read

The VMM type valve is a combination of two solenoid valve in an only compact and versatile valve huosing.

The first valve is a fast opening safety solenoid valve. The second valve may be a fast opening or a slow opening solenoid valve to adjust the gas flow, with a first adjustable fast stroke and a second adjustable slow stroke. It is possible connect a third by-pass / pilot valve, which performs by driver stage or to obtain a second fast (slow) stroke or both.

This type of device is suitable for air or gas blocking and releasing controls (with one or two stages operation), required in gas power burners, atmospheric gas boiler, industrial klins and in all gas equipments which use regulating trains.

Baca juga: Elektrogas automatic safety solenoid valves

Function and Application

The VMM type valve is a safety shutting device using auxiliary power supply. The first valve (A) is a fast opening safety solenoid valve.When it is de-energized, the spring pushes on the seal disc, keeping the gas passage closed. Now, the inlet chamber is under the gas line pressure, and it forces on the disc too, improving the seal.

If the power supply is shut off, the valve rapidly closes, interrupting the gas flow. Equally, the second valve (B) may be a fast opening or a slow opening solenoid valve to adjust the gas flow, with a first adjustable fast stroke and a second adjustable slow stroke. It is possible to connect a third by-pass valve (C), which works as low fire stage or to obtain a second fast (slow) stroke or both.Delta Elektrogas-VMM application and function

Specification

Connections Gas threaded ISO 7-1 from Rp3/4 to Rp2 or ANSI-ASME B1.20 from 3/4″ NPT to 2″NPT
Flanged PN16 – ISO 7005 from DN40 to DN80 or ANSI-ASA-ASME B16.5 class 150 from 2″ to 3″
By-pass size DN15 or DN25
Voltage rating 230 VAC 50/60 Hz
120 VAC 50/60 Hz
110 VAC 50/60 Hz
24 VAC/DC
Voltage tolerance -15% / +10%
Power consumption 70W for 3/4″ – 1″
90W (working) for 1″1/4-3″
by-pass 1/2″ 25W
by-pass 1″ 35W
Ambient temperature
Media temperature
-15 C / +60C (+5F to +140F)
Max. operating pressure 200 mbar (3 psig)
500 mbar (5 psig)
Body test pressure 1 bar (15 psig)
Flow capacity see charts
Closing time < 1 second
Opening time Adjustable
Pressure ports G1/4 (add. G1/8 into flange models)
Gas trainers 600 m (0.02 in), metal mesh
Enclosure IP54 (NEMA 3)
Optional IP65 with cable (NEMA 4)
Cable gland M20x1,5 for terminal box
PG 9 for ISO plug
Wires cros-section 2,5 mm2 max. (AWG 12) for terminal board
1,5 mm2 max (AWG 14) for ISO plug
Electrical safety Class I (EN 60335-1)
Coil winding insulation Class H (200C, 392F)
Coil thermal resistance Class F (155C, 311F)

Data Sheet Delta Elektrogas-VMM