Flowmasonic

Dwyer UFC Series Ultrasonic Flow Transmitter Set

2 minutes, 6 seconds Read

Dwyer UFC Series Ultrasonic Flow Transmitter Set utilizes the transit-time difference for measuring flow rates in pipes non-invasively. This is the permanent model, allowing the user to mount the converter on a surface or pipe and easily clamp on the sensors and guide bar. The easy-to-use compact and lightweight design is intended for mechanical devices using ideally homogeneous liquids that contain no air pockets.

The Series UFC by Dwyer Ultrasonic Flow Transmitter comes with a sturdy IP65 rating, protecting it from dust and direct water contact. The Series UFC has data logging capability, and additionally comes with USB output as well as 4 to 20 mA and pulse output capabilities.

Dwyer UFC Series Features

  • Kit Includes:
  • Converter
  • Set of Transducers
  • Ruled Guide Rail
  • Steel Banding
  • Banding Clips
  • Set of Transducer Cables
  • Set of High Temperature Interface Cables
  • Type ‘A’ to Type ‘B’ USB Communications Cable
  • USB Memory Stick
  • Ultrasonic Coupling Grease

Principles Of Operation

Two sensors are placed on the exterior of the pipe, and each transmits an ultrasonic pulse through the pipe and fluid to the other. The velocity of the liquid flowing through the pipes causes the pulse to accelerate or decelerate.

The difference in the transit times of the two pulses is used to calculate the flow rate. The use of transit time allows the flowmeter to be unaffected by pressure or temperature changes.

Application

  • Treated Water
  • River Water
  • Sea Water
  • Potable Water
  • Demineralized Water
  • Glycol/water mix
  • Hydraulic System
  • Diesel Oil
  • Flow Rate
Another Article:

Dwyer UFC Series Specification

Service Homogeneous liquids that do not contain more than 3% of air bubbles or particulate and capable of ultrasonic wave propagation.
Inputs TNC cable from sensors.
Range 0.33 to 33 ft/s (0.1 to 10 m/s) .
Display 240 x 64 pixel graphic display, high contrast black on white with backlight. Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5″ W x 1.3″ H (5 x 33.02 mm).
Accuracy > ±0.5 to ±2% of flow reading of flow rate > 0.03 ft/s (0.01 m/s) and pipe OD > 3.0 in (75 mm); ±3% of flow reading for flow rate > 0.03 ft/s (0.01 m/s) and pipe OD 0.5 to 3 in (13 to 75 mm); ±6% of flow reading for flow rate < 0.03 ft/s (0.01 m/s).
Power Requirements 86 to 264 VAC (50 to 60 Hz) or 24 VAC/VDC (1 A max.).
Power Consumption 10.5 W.
Temperature Limits
>Transducer: -4 to 275°F (-20 to 135°C);
Controller: -4 to 122°F (-20 to 50°C).

Download Data Sheet: Series UFC Ultrasonic Flow Transmitter Set

Ref: dwyer-inst.com

Similar Posts