for use with conductive liquids in 1 to 48″” pipe. A choice of
materials (stainless steel, brass, and PVC) allows the meter
to adapt to a range of temperature, pressure, and corrosive
environments.
changing viscosities and pulsating flows, such as air-driven
diaphragm pumps. With no moving parts, these meters can
be used in “dirty water” applications where debris would foul a
mechanical meter. Like all magmeters, when used in chemical
injection applications, these meters should be installed upstream
of the chemical line (or far enough downstream to allow complete
mixing of fluids before the meter).
Designed for modularity and versatility, the EX Series has
a current-sinking pulse output that can be combined with the
appropriate transmitter or indicator for the application.
rate/total and pulse output, the FT430 is best. For analog output
and display of rate and total, the FT440 can be used. Blind
analog output is provided by the AO55. The PD10 can be used to
divide the pulse for pacing chemical metering pumps. Electronic
modules can be wall- or meter- mounted. If the EX meter is
used with a programmable controller, the output signal can be
fed direct, with no other conditioning required.
EX-Series fi xed depth insertion meters require special fittings.
Factory installation in the fi tting ensures correct depth placement
in the pipe.
power model when a source of electricity is available, or in a low
power model that can run on an external battery with solar panel.
Reverse fl ow output and immersibility are optional
There are three types of Insertion Magnetic Flow meter
EX800-Series insertion electromagnetic flowmeters are designed |
|
The EX100 Series are adjustable depth insertion magmeters |
|
The EX200-Series are adjustable depth insertion magmeters |