TRICOR TCM 0325 Mass Flow Meter
TRICOR CLASSIC Series TCM 0325 Coriolis Mass Flow Meter memiliki laju aliran massa maksimum 325 kg / jam (12 lb / mnt) atau 49 bbl / hari dan ukuran nominal DN4 (1/8 “), dan nilai untuk tekanan proses hingga 200 bar (2900 psi). Akurasi standar untuk TCM 0325 adalah 0,3%. Tetapi dengan kalibrasi khusus, akurasi 0,1% dimungkinkan. Desain tabung bentuk berlian (bentuk-D) memiliki kinerja keseluruhan terbaik dari semua bentuk tabung Coriolis. Keuntungan mekanis dari desain ini termasuk rasio signal-to-noise terbaik dan mengurangi efek getaran eksternal, sehingga meningkatkan stabilitas nol.
Mass Flow Rate (max.): | 325 kg/h | 12 lb/min |
Volumetric Flow Rate (max.): | 325 l/h | 1.43 gpm, 49 bbl/d (US) |
Pressure Rating: | 200 bar | 2,900 psi |
Nominal Meter Size: | DN4 | 1/8″ |
Technical Data
FLOW RATE | |
Mass Flow Rate (max.): | 325 kg/h, 12 lb/min |
Volumetric Flow Rate (max.): | 325 l/h, 1.43 gpm, 49 bbl/d (US) |
PRESSURE | |
Standard Pressure Rating: | up to 200 bar, 2900 psi (option: up to 345 bar, 5,000 psi)¹ |
ACCURACY (LIQUIDS)² | |
Basic Accuracy (Mass flow)³: | ±0.3 % (option: up to ±0.1 %) of flow rate |
Mass Flow Repeatability: | ±0.05 % of flow rate |
Basic Accuracy (Volume flow)³: | ±0.4 % (option: up to ±0.15 %) of flow rate |
Volume Flow Repeatability: | ±0.05 % of flow rate |
Zero Stability: | ±0.01 % of full scale |
ACCURACY (GASES) | |
Basic Accuracy (Mass flow)³: | ±1 % (option: up to ±0.5 %) of flow rate |
Mass Flow Repeatability: | ±0.25 % of flow rate |
DENSITY | |
Density Range: | up to 2500 kg/m³, 2.5 g/cm³ |
Density Accuracy:³ | ±5.0 kg/m³ (option: ±1.0 kg/m³), ±0.005 g/cm³ (option: ±0.001 kg/m³) |
Density Repeatability: | ±0.5 kg/m³, ±0.0005 g/cm³ |
TEMPERATURE | |
Process Temperature Range: | Standard: -40 °C … +100 °C (-40 °F … +212 °F ) |
Optional: -60 °C … +200 °C (-76 °F … +392 °F ) | |
Temperature Accuracy: | ±1 °C ±0.5 % of reading (±1.8 °F ± 0.5% of reading ) |
Temperature Repeatability: | ±0.2 °C (±0.36 °F ) |
MATERIALS OF CONSTRUCTIONS (wetted parts) | |
Tubes: | 1.4404/AISI 316L |
Case: | 1.4404/AISI 316L |
Flow splitter: | 1.4404/AISI 316L |
Brazing Alloy: | BNi-2 |
EX CERTIFICATIONS | |
ATEX (Ex): | Zone 1: Group IIC or IIB, T2…T4 |
ATEX (Exn): | Zone 2: II 3G Ex nA IIC T2…T4 Gc |
IECEx (Ex): | Zone 1: Group IIC or IIB, T2…T4 |
cCSAus (Ex1): | Class I, Division 1: Group A, B, C, D or C, D, T2…T4 |
For Ex1, Ex3, EAC (TR-CU) the electronic is only available in an aluminum housing. | |
ATEX + IECEx + cCSAus triple approval (Ex3): | Zone 1: Group IIC or IIB, T2…T4 and Class I, Division 1: Group A, B, C, D or C, D, T2…T4 |
For Ex1, Ex3, EAC (TR-CU) the electronic is only available in an aluminum housing. Only with remote electronics. | |
EAC (TR-CU): | Group IIC or IIB, T2…T4 |
For Ex1, Ex3, EAC (TR-CU) the electronic is only available in an aluminum housing. |
¹The 200 bar standard pressure rating is per ASME. The 345 bar option is non-ASME rated.
²Stated flow accuracy combines the effects of repeatability, linearity and hysteresis.
³Calibration certificate options for higher accuracy are available.